• Dielectric withstand (0.1 kV - 5 kV, up to 500 mA, 500 VA)
  • Continuity - low resistance ( up to 9.999 Ohm @ 10/25 Aac; up to 999.9 Ohm @ 0.1/0.2 Aac; 4 wires measuring system)
  • Voltage drop (up to 100 V scaled to 10 Aac)
  • Insulation resistance (up to 999 MOhm @ 250 Vdc, 500 Vdc and 1000 Vdc)
  • PE leakage current (up to 20 mA)
  • Substitute leakage current
  • Touch leakage current
  • Functional (Active Power and Apparent Power up to 3500W, 40 V, 15.9 A, cos Phi 0 - 1, 45Hz - 65Hz)
  • Discharge time (0 - 10 s @ safe levels 60 V, 120 V)
  • Ingress protection (up to IP67) and Impact code (up to IK10)
  • Temperature (up to 700 °C)
  • Clearance and Creepage distances

And other electrical safety testing methods that we carry out in our laboratory, on-site or we subcontract with our partner laboratories.